Description
The database backup function in Delta Electronics InfraSuite Device Master Versions 00.00.01a and prior lacks proper authentication. An attacker could provide malicious serialized objects which, when deserialized, could activate an opcode for a backup scheduling function without authentication. This function allows the user to designate all function arguments and the file to be executed. This could allow the attacker to start any new process and achieve remote code execution.
CVSS breakdown
CVSS 3.1
Attack Vector
Network
Attack Complexity
Low
Privileges Required
None
User Interaction
None
Scope
Unchanged
Confidentiality
High
Integrity
High
Availability
High
Affected products
- Delta Electronics / InfraSuite Device Master0 – 00.00.01a
References
- VENDOR_ADVISORYhttps://www.cisa.gov/uscert/ics/advisories/icsa-22-298-07