Description
Campbell Scientific dataloggers CR6, CR300, CR800, CR1000 and CR3000 may allow an attacker to download configuration files, which may contain sensitive information about the internal network. From factory defaults, the mentioned datalogges have HTTP and PakBus enabled. The devices, with the default configuration, allow this situation via the PakBus port. The exploitation of this vulnerability may allow an attacker to download, modify, and upload new configuration files.
CVSS breakdown
CVSS 3.1
Attack Vector
Network
Attack Complexity
Low
Privileges Required
None
User Interaction
None
Scope
Unchanged
Confidentiality
High
Integrity
High
Availability
None
Affected products
- Campbell Scientific / CR1000all version – all version
- Campbell Scientific / CR300all version – all version
- Campbell Scientific / CR3000all version – all version
- Campbell Scientific / CR6all version – all version
- Campbell Scientific / CR800all version – all version