Description
FactoryTalk Linx, in the Rockwell Automation PanelView Plus, allows an unauthenticated threat actor to read data from memory via crafted malicious packets. Sending a size larger than the buffer size results in leakage of data from memory resulting in an information disclosure. If the size is large enough, it causes communications over the common industrial protocol to become unresponsive to any type of packet, resulting in a denial-of-service to FactoryTalk Linx over the common industrial protocol.
CVSS breakdown
CVSS 3.1
Attack Vector
Network
Attack Complexity
Low
Privileges Required
None
User Interaction
None
Scope
Unchanged
Confidentiality
Low
Integrity
None
Availability
High
Affected products
- Rockwell Automation / FactoryTalk Linx6.20 – 6.20
- Rockwell Automation / FactoryTalk Linx6.30 – 6.30