Description
A vulnerability has been identified in SIMATIC CN 4100 (All versions < V4.0.1). The affected application exhibits inconsistent SNMP behavior, such as unexpected service availability and unreliable configuration handling across protocol versions. This could allow an attacker to access sensitive data, potentially leading to a breach of confidentiality.
CVSS breakdown
CVSS 4.0
Attack Vector
Network
Attack Complexity
Low
Attack Requirements
None
Privileges Required
High
User Interaction
None
Confidentiality (Vulnerable System)
High
Integrity (Vulnerable System)
None
Availability (Vulnerable System)
None
Confidentiality (Subsequent System)
None
Integrity (Subsequent System)
None
Availability (Subsequent System)
None
CVSS 3.1
Attack Vector
Network
Attack Complexity
Low
Privileges Required
High
User Interaction
None
Scope
Unchanged
Confidentiality
High
Integrity
None
Availability
None
Affected products
- Siemens / SIMATIC CN 41000 – V4.0.1
Updated 38m ago · 8 sources