PublicCVE

CVE-2026-12183

CRITICAL9.3JSON exportCreate alert

Description

Nefteprodukttekhnika BUK TS-G Gas Station Automation System 2.9.1 through 2.10.2 on Linux contains an Improper Authentication vulnerability (CWE-287) in the system configuration module. The /php/ajax-login.php endpoint returns userid=1 (administrator) in response to any HTTP POST request that supplies arbitrary credentials (e.g., action=dologin&login=<any_value>&pwd=<any_value>), and subsequent privileged endpoints under /php/ajax-main.php and /modules/* do not validate a server-side session. A remote unauthenticated attacker can invoke any administrative action exposed by the configuration module, including reading and modifying user rules, fuel tank gauges, fuel dispensers, relays, cash registers, bank terminals, fuel cards, price and customer displays, cash collection, and pricing rules.

CVSS breakdown

CVSS 4.0
Attack Vector
Network
Attack Complexity
Low
Attack Requirements
None
Privileges Required
None
User Interaction
None
Confidentiality (Vulnerable System)
High
Integrity (Vulnerable System)
High
Availability (Vulnerable System)
High
Confidentiality (Subsequent System)
Low
Integrity (Subsequent System)
Low
Availability (Subsequent System)
Low
CVSS 3.1
Attack Vector
Network
Attack Complexity
Low
Privileges Required
None
User Interaction
None
Scope
Unchanged
Confidentiality
High
Integrity
High
Availability
High