PublicCVE

CVE-2026-25787

CRITICAL9.3Cross-site scripting

Description

Affected devices do not properly validate and sanitize Technology Object (TO) name rendered on the "Motion Control Diagnostics" page of the web interface. This could allow an authenticated attacker who is authorized to download a TIA project into the product, to inject malicious scripts into the page. If a benign user with appropriate rights accesses the "Motion Control Diagnostics" parameters page, the malicious code would be executed in the scope of their web session.

CVSS breakdown

CVSS 4.0
Attack Vector
Network
Attack Complexity
Low
Attack Requirements
None
Privileges Required
High
User Interaction
Passive
Confidentiality (Vulnerable System)
High
Integrity (Vulnerable System)
High
Availability (Vulnerable System)
High
Confidentiality (Subsequent System)
High
Integrity (Subsequent System)
High
Availability (Subsequent System)
High
CVSS 3.1
Attack Vector
Network
Attack Complexity
Low
Privileges Required
High
User Interaction
None
Scope
Changed
Confidentiality
High
Integrity
High
Availability
High

Affected products