Description
A vulnerability has been identified in SINEC INS (All versions < V1.0 SP2 Update 6). The affected application uses a password hashing implementation with a static, hardcoded salt shared across all users and installations, and is configured with an insufficient number of iterations. This could allow an attacker to efficiently recover user passwords using brute-force or precomputed attacks, potentially resulting in unauthorized access.
CVSS breakdown
CVSS 4.0
Attack Vector
Local
Attack Complexity
High
Attack Requirements
Present
Privileges Required
High
User Interaction
None
Confidentiality (Vulnerable System)
Low
Integrity (Vulnerable System)
None
Availability (Vulnerable System)
None
Confidentiality (Subsequent System)
High
Integrity (Subsequent System)
High
Availability (Subsequent System)
High
CVSS 3.1
Attack Vector
Local
Attack Complexity
High
Privileges Required
High
User Interaction
None
Scope
Changed
Confidentiality
High
Integrity
High
Availability
High
Affected products
- Siemens / SINEC INS0 – V1.0 SP2 Update 6